Ensurepass.com : Ensure you pass the IT Exams
2018 Jan VMware Official New Released VCI550
100% Free Download! 100% Pass Guaranteed!
http://www.EnsurePass.com/VCI550.html
VMware Certified Instructor on vSphere 5
Question No: 51 – (Topic 2)
A system administrator has an application installed on a physical machine that is licensed to the MAC address of the physical NIC. This system needs to be virtualized.
What two methods could an administrator use to ensure the license will function in the virtual machine? (Choose two.)
-
Manually set the MAC address for the vNIC in the guest OS
-
Install the NIC from the physical server into the ESXi host
-
Manually set the MAC address for the vNIC using the Web Client
-
Configure the physical server#39;s MAC address in the virtual switch
Answer: A,C
Question No: 52 – (Topic 2)
– Exhibit –
– Exhibit –
A vSphere administrator assigns VLAN 3389 to the Production port group on the VCP_DCV_Example vSphere Distributed Switch. After the change, users report a loss of connectivity to their applications. Further analysis provides the following data:
The cluster has not had a ESXi host failure.
Application functioned normally prior to the change.
The loss of connectivity occurred immediately following the change. Which condition would cause this loss of connectivity?
-
The physical switch ports used by the vmnics have not been configured with 802.1Q.
-
Maintenance Mode was initiated on one of the hosts in the cluster. Connectivity will resume after the virtual machines are migrated.
-
All uplinks were removed from the VCP_DCV_Example switch and added to another virtual switch.
-
A load balancing setting on the port group conflicts with the load balancing setting of the switch.
Answer: A
Question No: 53 – (Topic 2)
Why would an administrator be unable to locate an IP address for a vSphere vmnic uplink?
-
IP addresses are defined at the virtual nic level, not the vmnic level.
-
ESXi host vmnics communicate with physical switches on layer 3.
-
ESXi hosts use NAT translation to mask the actual vmnic IP address.
-
The IP address of the vmnic is not shown in the vSphere Client.
Answer: A
Question No: 54 – (Topic 2)
A network auditing team has observed activity from a virtual machine that may be an organization policy security breach. The vSphere administrator needs to stop network traffic from the virtual machine.
Which step should the administrator take?
-
Enable Port Blocking on the vSphere Standard Switches in the organization and block the port on which the virtual machine is connected.
-
Enable Port Blocking on each vSphere Standard Switch portgroup in the organization, then block the port on which the virtual machine is connected.
-
Enable Port Blocking on each vSphere Distributed Switch portgroup in the organization, then block the port on which the virtual machine is connected.
-
Enable Port Blocking on the vSphere Distributed Switches in the organization and block the port on which the virtual machine is connected.
Answer: C
Question No: 55 – (Topic 2)
An application administrator reports application slowness when loading the application#39;s web portal. The virtual machine is currently connected to a vSphere Distributed Switch. The application owner requests information about the virtual machine#39;s network traffic.
Which feature of a vSphere Distributed Switch should the administrator use to gather the needed information?
-
NetFlow
-
Port Mirroring
-
Network I/O Control
-
Promiscuous Mode
Answer: A
Question No: 56 – (Topic 2)
– Exhibit –
– Exhibit –
Why is the network configuration shown in the exhibit impossible?
-
A single vmnic cannot be shared by two virtual switches.
-
The MAC address of the Management Network VMkernel port is invalid.
-
Virtual machines are not allowed to run on the same virtual machine port group as the vCenter Server Virtual Appliance.
-
Virtual Machine Port Groups and VMkernel Ports are not allowed on the same virtual switch.
Answer: A
Question No: 57 – (Topic 2)
– Exhibit –
– Exhibit –
An administrator is unable to configure Receive Side Scaling on the vmnic driver in a Windows 2008 R2 guest.
Based on the exhibit, what would need to be modified to enable this option?
-
Manually configure a static MAC address
-
Enable DirectPath I/O
-
Ensure the vmnic is attached to the correct network
-
Change the adapter type to VMXNET3
Answer: D
Question No: 58 – (Topic 2)
The Edit Settings wizard reports a virtual machine is configured as follows:
– Exhibit –
– Exhibit –
Which setting, if NOT configured, will prevent network connectivity?
-
The network label must be supplied.
-
The MAC address must be supplied.
-
The device status must be set to Connected.
-
The DirectPath I/O status must be Supported.
Answer: A
Question No: 59 – (Topic 2)
A vSphere administrator has created a vSphere Standard Switch with one virtual machine port group and one physical uplink. The administrator needs to ensure that the virtual machines on this port group can communicate only with each other.
What should the administrator do?
-
Remove the physical uplink from the vSphere Standard Switch
-
Create a Private VLAN and apply it to the virtual machine port group on the vSphere Standard Switch
-
Enable Port Security on the vSphere Standard Switch
-
Enable the Fenced setting on the virtual machine port group
Answer: A
Question No: 60 – (Topic 2)
A vSphere administrator needs to add redundancy to an ESXi 5.x management network on a vSphere Standard Switch.
Which method should the administrator use to create redundant management networks?
-
Configure the management network vSwitch with two active uplinks
-
Configure an additional management portgroup on the same vSwitch
-
Create a second management network on a second vSwitch in the same subnet
-
Create a second management network on the same vSwitch in the same subnet
Answer: A
100% Ensurepass Free Download!
–Download Free Demo:VCI550 Demo PDF
100% Ensurepass Free Guaranteed!
–VCI550 Dumps
EnsurePass | ExamCollection | Testking | |
---|---|---|---|
Lowest Price Guarantee | Yes | No | No |
Up-to-Dated | Yes | No | No |
Real Questions | Yes | No | No |
Explanation | Yes | No | No |
PDF VCE | Yes | No | No |
Free VCE Simulator | Yes | No | No |
Instant Download | Yes | No | No |
100-105 Dumps VCE PDF
200-105 Dumps VCE PDF
300-101 Dumps VCE PDF
300-115 Dumps VCE PDF
300-135 Dumps VCE PDF
300-320 Dumps VCE PDF
400-101 Dumps VCE PDF
640-911 Dumps VCE PDF
640-916 Dumps VCE PDF
70-410 Dumps VCE PDF
70-411 Dumps VCE PDF
70-412 Dumps VCE PDF
70-413 Dumps VCE PDF
70-414 Dumps VCE PDF
70-417 Dumps VCE PDF
70-461 Dumps VCE PDF
70-462 Dumps VCE PDF
70-463 Dumps VCE PDF
70-464 Dumps VCE PDF
70-465 Dumps VCE PDF
70-480 Dumps VCE PDF
70-483 Dumps VCE PDF
70-486 Dumps VCE PDF
70-487 Dumps VCE PDF
220-901 Dumps VCE PDF
220-902 Dumps VCE PDF
N10-006 Dumps VCE PDF
SY0-401 Dumps VCE PDF